WOODWARD 8237-1600 Speeding safety devices

8237-1600 Technical Specifications
Dimensions 13 x 17.5 x 6.25 (inches)
Enclosure Type IP56 dust and water resistant (Installed properly)
Features Overvoltage protection II (per IEC 60664-1)
Input Voltage 2 High Voltage Inputs OR 1 High Voltage and 1 Low Voltage
Inrush Current 10 A at 115 Vac, 20 A @ 220 Vac
Keypad/Display 4.2in display and 15 Keys Per Module
Operating Temperature –20 to +60 °C at 95% humidity
Storage Temperature –20 to +65 °C at 95% humidity
Woodward has ceased production of this turbine safety device.

Get A Quote
Contact Us

The ProTech-GII is an overspeed safety device designed to safely shut down steam, gas, and hydro turbines of all sizes upon sensing an overspeed or overacceleration event.

8237-1600 Technical Specifications
Dimensions 13 x 17.5 x 6.25 (inches)
Enclosure Type IP56 dust and water resistant (Installed properly)
Features Overvoltage protection II (per IEC 60664-1)
Input Voltage 2 High Voltage Inputs OR 1 High Voltage and 1 Low Voltage
Inrush Current 10 A at 115 Vac, 20 A @ 220 Vac
Keypad/Display 4.2in display and 15 Keys Per Module
Operating Temperature –20 to +60 °C at 95% humidity
Storage Temperature –20 to +65 °C at 95% humidity
Weight Less than 23 lbs

Model 8237-1600 can be configured to work with any size turbine, as long as it is powered by steam, gas, or water. Speed readouts for this over acceleration device are between 4 and 20 mA. This model will safely shut down any size turbine if it begins to dangerously speed up. The panel mount has a backplane structure making repairs and replacements easy. Model 8237-1600 can be easily integrated into any turbine system, and it comes with Modbus communications. It’s equipped with MPU detection in addition to acceleration detection.

It uses three independent trip relays, as well as low and high voltage power inputs. model 8237-1600 also features a triple opt-in voting structure. This overspeed detection device has a triple module design which makes it possible to carry out maintenance while the system is still online. One module can work while the other two are operating. The product 8237-1600 can also perform regular speed tests with the internal generator and frequency.

Woodward Control Systems Woodward USA has designed and manufactured the Woodward 505 control system, a microprocessor-based control system for single or dual actuator steam turbines. The Woodward 505 control system has two modes of operation: programming mode and operating mode. The programming mode is used to select the internal configuration of the controller and the setting of the operating mode; the operating mode implements the control according to the set program. The turbine electronic governor; the turbine electro-hydraulic converter; the control signal output from the Wood Ward 505 is converted into a hydraulic signal by the I/H converter to control the opening of the main steam door of the steam turbine compressor for the purpose of controlling the turbine compressor speed. The Woodward 505 electronic governor is used to control the speed of the turbocompressor.
Woodward products, Woodward electronic governor woodward505,woodward woodward505e,woodward woodward505c,woodward woodward505h; controller 2301D-ST AtlasPCTM MicroNetTM NetSimTM software Human Machine Interface (HMI) 5009 505/505E 505View software PEAK150; mechanical governors TG PG PG-PL UG-5.7,-8,&-10 UG40 governors; actuators EHPC EML100 TM25/- 200LP hydraulic amplifiers TG13E/TG17E PGPL UG40 UG CPC. woodward 505,woodward 505e,woodward 505c,woodward 505h, TG-13Woodward Governor Company Woodward Governor Company product range.
Woodward Woodward 505 electronic governors are used to control the speed of turbine compressors.

9907-164
8272-582
723 PLUS DIGITAL CONTROL
9907-167
9907-162
2301E
8200-1302
8440-1884
9905-068
9907-163
9907-166
9987-814
8440-1884M
9907-014
8280-1001 9906-619
9905-144
9905-020
9907-186
9907-205
9907-018
9907-019
Scroll to Top