GE

SR469-P5-HI-A20-E-H Motor management relays

SR469-P5-HI-A20-E Technical Specifications

Analog Current Output Accuracy 1200 Ω
Analog Outputs 4-20 mA
Certifications ISO, UL, CSA and CE
Control Power 90 to 300 VDC
Humidity 95%, non-condensing
Operate Time Output Relays 10 ms
Phase Differential Instanteous Timing Accuracy +50 ms
RTD Sensing Current 5mA
Storage Temperature –40°C to +80°C
Terminals #8 ring lug, 10 AWG wire std

Xiamen Xiongba Electronic Commerce Co. LTD

FROM:Mr. Wei

E-Mail:2322181769@qq.com                                                                                               

TEL/WeChat:15396237607

Get A Quote
Contact Us

The SR469-P5-HI-A20-E is from GE Multilin and is part of the SR469 motor management relay family. The unit is designed with a 5 amp phase CT secondary coil.The SR 469 relay is designed for use with medium voltage motors and provides integrated management and protection.

The SR469-P5-HI-A20-E provides 70-265 volts AC, 90-300 volts DC control power. The unit has an enhanced front panel. However, if you require a unit that can be used in harsh environments, please refer to our SR469-P5-HI-A20-E-H listing, which is similar to this unit in all respects except for an additional harsh environment conformal coating.

SR469-P5-HI-A20-E Technical Specifications

Analog Current Output Accuracy 1200 Ω
Analog Outputs 4-20 mA
Certifications ISO, UL, CSA and CE
Control Power 90 to 300 VDC
Humidity 95%, non-condensing
Operate Time Output Relays 10 ms
Phase Differential Instanteous Timing Accuracy +50 ms
RTD Sensing Current 5mA
Storage Temperature –40°C to +80°C
Terminals #8 ring lug, 10 AWG wire std

The R469-P5-HI-A20-E has a well designed front panel that is easy to use. The panel includes an RS-232 program port interface with a baud rate of 9600 and is programmable up to 19200 baud. This panel has a pull-out handle which can be sealed to prevent any unauthorised movement. The front panel has a large LCD display which can show up to 40 characters. This display allows the user to see diagnostic information such as trips or alarms locally. In addition, the panel has motor and output status indicators, device indicators, a numeric keypad, control and programming keys including reset, exit and menu buttons, and numeric keys that allow the user to change set values.

369-HI-0-0-0-0
489-P5-LO-A20
DS200ADGIH1AAA
DS200TCQAG1BHF
SR469-P5-HI-A20
SR469-P5-HI-A20-E
VMIPMC-5565
IC698CPE030
HYDRAN M2
IC660ELB912
VMIVME-7807

Scroll to Top