140CPS12400
Power supply module Modicon Quantum – 115 V/230 V AC – Redundant
Input voltage 115 V (93… .138 V) .138 V) AC 47…63 Hz
230 V (170… .276 V) AC .276 V) AC
Input current 1100 MA on … 115 V
600 MA on … 230 V
Maximum inrush current 19 A 230 V
38 A 115 V
Rated power [VA] 130 VA
Fuse for use with relay 2 A, slow-break type
Harmonic distortion <= 10 % basic RMS
Output voltage 5.1 V dc
Supply output current 8 A 60 °C redundant
Output overvoltage protection Internal
Output overload protection Internal
Power consumption 6 + (1.5 x output current) where output current in A
Local signal indication 1 LED (green) power supply (PWR OK):
Marking CE
Module classification Standard
Product net weight 0.65 Kg
I/O card redundancy: Network card redundancy refers to the insertion of multiple network cards into a server. Originally used on mainframes and medium-sized machines, redundant NIC technology is now also becoming available for PC servers. Multiple NICs can share network traffic and are fault-tolerant.
CPU redundancy: The main processor in a system does not often fail, but symmetric multiprocessing (SMP) allows multiple CPUs to share the workload to provide some degree of fault tolerance.
140CPU31110 |
140CPU43412U |
140CPU65150 |
140CPU65160 |
140CPU65260 |
140CPU65860 |
140CPU67060 |
140CPU67160 |
140CPU67260 |
140CPU67261 |
140CPU67861 |
140CPU65160S |
140CPU67160S |
140SDI95300S |
140SDO95300S |
140SAI94000S |
140XBP00300 |
140XBP00400 |
140XBP00600 |
140XBP01000 |
140XBP01600 |
140XBE10000 |
1. CPU module
CPU module is mainly composed of microprocessor (CPU chip) and memory. In the PLC control system, the CPU module is equivalent to the human brain, which constantly collects input signals, executes user programs and refreshes the output of the system; the memory is used to store programs and data.
2. I/O module
Input (1nput) module and output (Output) module is referred to as I/O module, they are the eyes, ears, hands and feet of the system, is the bridge between external field devices and the CPU module.
Input modules are used to receive and collect input signals. Switching input modules are used to receive switching input signals from push buttons; selector switches, digital dip switches, limit switches, proximity switches, photoelectric switches, pressure relays, etc.; analogue input modules are used to receive continuously changing analogue current and voltage signals from potentiometers, speed generators and various transmitters.
The switching output module is used to control output devices such as contactors, solenoid valves, solenoids, indicators, digital display devices and alarm devices, while the analogue output module is used to control actuating devices such as regulating valves and frequency converters.
The working voltage of the CPU module is generally 5V, while the input/output signal voltage of the PLC is generally higher, such as 24V DC and 220V AC. the spike voltage and interference noise introduced from outside may damage the components in the CPU module, or make the PLC not work properly. In the I / O module, with photocouplers, phototransistors, small relays and other devices to isolate the internal circuit of the PLC and the external I / O circuit, I / O module in addition to the transfer of signals, there is a level conversion and isolation role.
Xiamen Xiongba Electronic Commerce Co. LTD
FROM:Mr. Wei
E-Mail:2322181769@qq.com
TEL/WeChat:15396237607
We do other brands: ABB, Allen-Bradley, Schneider, GE (General electric), Westinghouse, FANUC, Bently, KUKA, Foxboro, Triconex, Honwell, YASKAWA, etc., if you need, you can contact me, look forward to your consultation.