Triconex 3700A 0-5Vdc Analogue Input
Triconex 3700A0-5 VDC Differential, DC Coupled
The Triconex Tricon Safety Instrumented System is designed to meet the needs of safety and critical control applications in oil and gas, power, refining, chemicals, pharmaceutical and biotech industries. It is based on industry leading TMR technology, is easy to operate and maintain and provides the lowest total cost of ownership.
APPLICATIONS:
Emergency Shutdown (ESD)
Burner Management Systems (BMS)
Fire and Gas Systems (F&G)
High Integrity Pressure Protection systems (HIPPS)
Turbomachinery Controls (TMC)
Critical Control
An Expansion slot is a slot on the motherboard used to secure the expansion card and connect it to the system bus, also known as an expansion slot or expansion slot. Expansion slots are a way to add or enhance computer features and functions.
Chassis Assemblies:
Main Chassis, High-Density Configuration, includes the Tricon printed manuals Triconex8110
Expansion Chassis, High-Density Configuration Triconex8111
Expansion Chassis, Enhanced Low-Density Configuration Triconex8121
Remote Expansion Chassis, High-Density Configuration Triconex8112
Power module: The role of the power module is to isolate, protect (short circuit protection, overvoltage protection, undervoltage protection, overcurrent protection, other protection,) voltage exchange, voltage regulation, noise reduction and other functions.
Power Modules:
20 VAC/VDC – 175-Watt Power Module Triconex8310
24 VDC – 175-Watt Power Module Triconex8311
230 VAC – 175-Watt Power Module Triconex8312
Main processor module: The role of the processor module is to execute various instructions and data processing, which can be divided into three modules, namely, the control unit, the computing unit and the storage unit. Its role is to process instructions, execute operations, control time and process data, which directly affects the operation effect of the entire system
Main Processor Modules:
3008 Main Processor, 16 megabytes DRAM Triconex3008
Tricon Communication Module (TCM), Ethernet (802.3) and serial (RS-232/RS-485) ports
Triconex4351A, Triconex4352A,
Triconex4351B, Triconex4352B
Triconex4353, Triconex4354
Models 3502E, 3503E, and 3505E can self-test to detect stuck-On conditions where the circuitry cannot tell whether a point has gone to the Off state. Since most safety systems are set up with a deenergize-to-trip capability, the ability to detect Off points is an important feature. To test for stuck-On inputs, a switch within the input circuitry is closed to allow a zero input (Off) to be read by the optical isolation circuitry. The last data reading is frozen in the I/O communication processor while the test is running.
Digital Input Modules:
115 VAC/VDC Opto-Isolated, Non-Commoned Triconex3501E/3501T
48 VAC/VDC Commoned in Groups of 8, Self-Test Triconex3502E
24 VAC/VDC Commoned in Groups of 8, Self-Test Triconex3503E
24/48 VDC High-Density, DC Coupled Triconex3504E
24 VDC Low Threshold with Self-test, Commoned Triconex3505E
24 VDC Single, Opto-Isolated, Commoned Triconex3564
Pulse Input Differential, AC Coupled Triconex3511
Pulse Totalizer Opto-isolated, Non-commoned Triconex3515
Company main: Bentley Bently, Invensys TRICONEX, Woodward Woodward, FOXBORO, WESTINGHOUSE, Ryan, Schneider Schneider
Modicon, ABB, A-B (Allen-Bradley), Motorola MOTOROLA, GE Fanuc, YASKAWA Yaskawa, Bosch REXROIH, ACSO, YOKOGAWA Yokogawa, Dark Horse HIMA, EMERSON, Honeywell, Moore Moore, EPRO, ICS TRIPLEX, bachmann Bachmann and other major brands === = mainly do PLC DCS robot servo four systems of the discontinued spare parts module card driver