GE

IC697CBL811丨GE PLC Digital Module Cables

The VersaPoint station may include IC220MDL642, a Discrete Input Module manufactured by GE Fanuc Automation. This module has 4 logic points, and the lifecycle status is active. The input voltage is 0-30 VDC and the input response time is less than 1 msec. The LED indicator is Bus Diagnostics Status indication of inputs. The nominal current consumption of US is a maximum of 1.0 amperes. The on state current is 4 mA and the off state current is 0.4 mA. The current consumption for Local Bus UL is 40 mA. The connection style is a 2 and 3 wire connection.

Xiamen Xiongba Electronic Commerce Co. LTD
FROM:Mr. Wei
E-Mail:2322181769@qq.com
TEL/WeChat:15396237607

Get A Quote
Contact Us

IC697CBL811丨GE PLC Digital Module Cables
The VersaPoint station may include IC220MDL642, a Discrete Input Module manufactured by GE Fanuc Automation. This module has 4 logic points, and the lifecycle status is active. The input voltage is 0-30 VDC and the input response time is less than 1 msec. The LED indicator is Bus Diagnostics Status indication of inputs. The nominal current consumption of US is a maximum of 1.0 amperes. The on state current is 4 mA and the off state current is 0.4 mA. The current consumption for Local Bus UL is 40 mA. The connection style is a 2 and 3 wire connection.

The datasheet number for this module is GFK-1902, and the module ID is BE hex (190 decimal). Input/output modules have terminal points to accommodate 2-, 3-, and 4-wire sensors or actuators depending on the module. Connections are made to Terminal Strips, which are ordered separately. The electronics power loss of an I/O module can be calculated following the formula in the module’s datasheet. The power loss of the module must not exceed the power loss of the housing. Additional I/O module grounding beyond the voltage jumper FE is not required. Four digital sensors can be connected to the module. The housing dimensions are 0.480 in x 4.724 in x 2.795 in.

The operating humidity may occasionally reach 85% without incident. The maximum permissible load current per sensor is 250 mA. The maximum permissible load current from the terminal is 1.0A. This module has a class of protection at Class 3 according to VDE 0106 and IEC 60536. Protective devices on the module include protective circuits of the power terminal that protect against surge voltage and polarity reversal.

 

VMIVME-7750
IS220PVIBH1A
IS420UCSCH2A
5SHY3545L0010 3BHB013088R0001
3BHE009681R0101 GVC750BE101
ICS TRIPLEX T8310
ICS TRIPLEX T8461
ICS TRIPLEX T8151B
ICS TRIPLEX T8403C
ICS TRIPLEX T8311
ICS TRIPLEX T9402
ICS TRIPLEX T9451
IS215VCMIH2BB
IS215VCMIH2CA
ABB PM866K01 3BSE050198R1
ABB 216NG63
ABB 216VC62a
ABB 216EA61b
ABB 216AB61
ABB 216DB61
ABB REG216

PC control module, is based on PC as a basic development of a control terminal. PC control module is a programmable controller, is used for communication between PC and PC station terminal, mainly used to achieve control data communication function. PC control module has powerful functions, good compatibility, high security, cheap price, simple maintenance, support industrial environment and other characteristics. According to customer requirements for secondary development and production, with high cost performance. PC control module through serial communication technology and analog/digital communication technology and PLC, MCU and other control equipment to achieve communication, can be used in PLC, MCU and other control equipment.

We do other brands: ABB, Allen-Bradley, Schneider, GE (General electric), Westinghouse, FANUC, Bently, KUKA, Foxboro, Triconex, Honeywell, YASKAWA, etc., if you need, you can contact me, look forward to your consultation.

As long as tomorrow is still here, as long as spring is still here!
As long as there is life, as long as there is hope!
As long as tomorrow is still here, as long as the future is still here!

Scroll to Top