Yokogawa

Shinkawa Monitor VM-5P3 Phase Marker Unit

Shinkawa Monitor VM-5P3 Phase Marker Unit

Accommodated in a VM-5H3 or VM-5W1 Instrument Rack, these units process phasemarker signals, and provide OK alarm contact output and internal power supply voltagefailure detection.

Get A Quote
Contact Us

Shinkawa Monitor VM-5P3 Phase Marker Unit

Accommodated in a VM-5H3 or VM-5W1 Instrument Rack, these units process phasemarker signals, and provide OK alarm contact output and internal power supply voltagefailure detection.

Shinkawa Monitor VM-5P3 Phase Marker Unit

Product Recommendation:

Shinkawa VM-5 Series Monitor VM-5K/VM-5U Dual Vibration monitor

Shinkawa VM-5 Series VM-5W1 Dual Power Supply Instrument Rack

Shinkawa VM-5H3 Instrument Rack

Shinkawa VM-5W1 Dual Power Supply Instrument Rack – VM-5 Series

VM-5Z0 Power Supply Backup Module Unit – Shinkawa Monitor

VM-5Z1/VM-5Z2 Power Supply Unit – Shinkawa Monitor

VM-5Z3/VM-5Z4 Power Supply Unit – Shinkawa Monitor

Shinkawa Monitor VM-5P3 Phase Marker Unit

STANDARD SPECIFICATION

POWER SUPPLY:Supplied from instrument rack ( VM-5H3 or VM-5W1 )
INPUT TRANSDUCER:FK. RD series
SIGNAL:Phase marker 2ch Max. Qutput impedance : Approx.10k2
INPUT VOLTAGE RANGE:0 to 25VDC (VM-5P3)
BUFFER OUTPUT:
– Phase marker signal : 2ch
– Output impedance :50
PULSE OUTPUT:
– Shaped pulse signal is output via a buffer amplifier.
– Signal level : -1 to +1V (PL), 4 to 6V (PH)
TRANSDUCER POWER SUPPL:-24VDC+1- 1V,20mA
TEMPERATURE RANGE:
– Operating temperature : 0 to 65°C
– Storage temperature :-30 to +85°C
– Relative humidity : 20 to 95%RH (non-condensing)
MATERIAL AND FINISH:Face plate : Aluminum Munsell N-4.0 (equiv.)
MASS:Unit : Max. 0.6kg

 

VM-5K Dual Vibration Monitor:
Inputs signals from the FK’vK Series Vibration Transducers corresponding to 2 channels,Simultaneously provides 2 points of shaftnbration monitorina within one unit.

VM-5Y1,VM-5Y2,VM-5Y3 Relay Module Unit:

These units are designed for use with VM-5 Series Monitors. Mounted on the rear panel ofthe VM-5H3 or VM-5W1 Instrument Rack, they output contact signals such as inputabnormal, alert and danger alarms for sequence control. Using 10mm-pitch two columnlarge-sized terminal block, there is no complicated wiring involved.

VM-5Y4,VM-5Y5,VM-5Y6 Relay Module Unit:

These units are the connector type Relay Module. Mounted on the rear panel of the VM-5H3 orVM-5W1 Instrument Rack, VM-5Y4 and 6 can output the recorder output and alarm output signal,and VM-5Y5 can output the buffer output and alarm output signal through the D-sub connector.They also output contact signals of the sequence control for input abnormal, alert and dangeralarms from the terminal block. An arc suppressor (optional) absorbs the arc discharge betweencontacts to prevent damage to the internal circuits.

We still have a lot of products not on the line, you can contact me directly if you need

VM-5U Dual Seismic Monitor
Inpuls signals from the Cv Series VelocityTransducer corresponding to 2 channels.

VM-5P3 Phase Marker Unit
Accommodated in a VM-5H3 or VM-5W1 Instrument Rack, these units process phasemarker signals, and provide OK alarm contact output and internal power supply voltagefailure detection.

VM-53 Dual Communication Unit
This unit has two independent serial ports. While inserted in a relay module slot of theVM-5H3 or VM-5W1 instrument Rack, it collects static data in the rack by the Modbusprotocol and then sends it to an external host computer, in addition, as this unit can bedaisy chain-connected, it enables data collection from two or more racks.

VM-5Z1,VM-5Z2,VM-5Z3,VM-5Z4 Power Supply Unit
Provides DC power to each VM-5 Series unit mounted in the same instrument rack. Afault in the power supply is indicated by lighting of the power supply OK lamp and alarmcontact output.

Scroll to Top